Since 2010 we have manufactured over 25MW of our 6kW 19” rack load banks to customers across the world and the demands continues to grow.
Our global presence is supported from sales offices & rental depots in Manchester UK and from Hillstone Middle East in Dubai UAE.
Load banks are used for testing:
- Battery systemsLoad banks are used in sectors such as:
- Oil and GasHillstone also manufacture and supply:
- Battery chargers
Hillstone are pleased to announce Gen-Parts as our new load bank sales partner in Poland.
A range of generator load banks will soon be available online at www.gen-parts.pl
Hillstone are now an endorser to the European Code of Conduct for Datacentres with the ability to issue datacentre calibration reports under IST testing services focused on reducing energy useage and creating energy efficient operations.
Additional partner representation in Europe, Middle East and the Far East providing a local presence in Holland, Poland, Qatar, India, Saudi Arabia and Singapore. Hillstone extends our delivery of high quality engineering solution to your load testing requirements.
Hillstone’s UK Loadbank Rental Service offers DC load banks from 12V to 1200V up to 4500A DC and carries over 16MW of rental datacentre load banks including heatload server simulators and dedicated adiabatic specific load banks.
Hillstone Datacentre loadbanks have been used extensively across the world to allow commissioning teams to perform independent verification of Datacentre Calibration, Heat Load Testing, CFD Modeling, Integrated System Testing and support of Tier Certifications.
Our range of datacentre heat load solutions are all designed to emulate ASHRAE TC9.9 recommendations of operating IT equipment at higher ambient temperatures to reduce the running costs of datacentre cooling systems.
The available load banks include 19" rack mounted 4U server simulators, 20KW portable mini towers and 110KW 400V PDU loadbanks which allow synchronised controls from a single remote hand held controller.
Hillstone are pleased to announce Gen-Parts as our new load bank sales partner in Poland.
A range of generator load banks will soon be available online at www.gen-parts.pl
Hillstone are now an endorser to the European Code of Conduct for Datacentres with the ability to issue datacentre calibration reports under IST testing services focused on reducing energy useage and creating energy efficient operations.
Load banks are used for testing:
- Battery systemsLoad banks are used in sectors such as:
- Oil and GasHillstone also manufacture and supply:
- Battery chargersApplication Note 2
Battery Discharge testing is the approved method to determine the capacity of Lead acid and (Nickel Cadmium) Ni Cad/Ni Cd batteries, as recommended by all battery manufacturers such as Enersys, Exide, C&D Technologies, Hawker, Yuasa, Exide, Hoppecke, Saft, Varta, and in accordance to BS6290 part 4 / IEC TR 62060.