Load Banks & Battery Maintenance Software


Welcome to the Hillstone website

Offering worldwide load bank sales since 1995 to the standby power industry

Please visit load bank e-shop

Battlife is the new softare solution for battery maintenance - full details www.batt.life

Welcome to the Hillstone website

Offering worldwide load bank sales since 1995 to the standby power industry

Please visit load bank e-shop

Battlife is the new softare solution for battery maintenance - full details www.batt.life



DC Load Banks

DC Load Banks

DC Load Banks


DC Load Banks designed for
battery & fuel cell testing
12V to 1200V DC
up to 4500A

AC Load Banks

Portable - HAC Load Banks


AC Load Bank designed for testing
1 & 3ph Gensets and UPS Systems
3kW to 1500kW

HeatLoad

Heatload

Gyron Hemel IST


Datacentre IST &
UTI Tier Certifications


The NEW HAC230-8RM[PDF] is a high powered sever simulator which delivers a low delta T of 11oC against a typical server performance of 2100cm/h released Qtr3 2018 to a major European datacentre

Hire Load Banks

Rental Load Banks






Load Bank Rental Service


Hillstone design & manufacture an extensive range of load banks for AC - UPS & Genset testing and DC - standby battery & lithium-ion discharge testing.

From the UK factory & rental depot our global presence includes: Hillstone Middle East sales office in Dubai, UAE and sales partners across the world.

Additional partner representation in Europe, Middle East and the Far East provides a local presence in Holland, Qatar, India and Saudi Arabia.

Application Note 1

Regular load bank testing of generators provides an essential health check service to prevent diesel engine failure due to wet stacking.
Wet stacking occurs due to under loading of the genset which results in wet un-burned fuel building up in the engine.
This fuel build up will over time line the combustion chamber cylinders and cause a reduction of the engines rating and efficiency which will ultimately cause premature failure of the generator. Running the generator on load of 50% - 100% of the genset rating will allow the engine to reach the recommend operating temperature, which will burn off the choke deposits.

Application Note 2

Battery Discharge testing is the approved method to determine the capacity of Lead acid and (Nickel Cadmium) Ni Cad/Ni Cd batteries, as recommended by all battery manufacturers such as Enersys, Exide, C&D Technologies, Hawker, Yuasa, Exide, Hoppecke, Saft, Varta, and in accordance to BS6290 part 4 / IEC TR 62060.


Application Note 1
Regular load bank testing of generators provides an essential health check service to prevent diesel engine failure due to wet stacking. Wet stacking occurs due to under loading of the genset which results in wet un-burned fuel building up in the engine. This fuel build up will over time line the combustion chamber cylinders and cause a reduction of the engines rating and efficiency which will ultimately cause premature failure of the generator. Running the generator on load of 50% - 100% of the genset rating will allow the engine to reach the recommend operating temperature, which will burn off the choke deposits.

Application Note 2
Battery Discharge testing is the approved method to determine the capacity of Lead acid and (Nickel Cadmium) Ni Cad/Ni Cd batteries, as recommended by all battery manufacturers such as Enersys, Exide, C&D Technologies, Hawker, Yuasa, Exide, Hoppecke, Saft, Varta, and in accordance to BS6290 part 4 / IEC TR 62060.